At HZ, we provide insulation mats varying in specifications and thickness.

  •         Available in sheets or rolled
  •         Thickness: 1mm-15mm (custom available)
  •         Shore A hardness
  •         Weather resistant
  •         Ozone and UV resistant
  •         Suitable for 1000V-36000V

Leading Insulating Mats Supplier in China

We offer insulating mats made from high-grade rubber compounds with non-conductive and highly electrical-resistant feature. These mats provide superior electrical safety for medium and high voltage environments including 3.3kV, 6.6kV, 11kV, 15kV, and more installations.

Our mats are moisture-resistant and waterproof. These are also designed with oil and acid resistance and fire retardant properties. Therefore, ensuring durability and long-lasting life.

Each mat we produce is tested to meet international electrical insulation standards. You can assure that they have excellent resistance against punctures, impact, and mechanical wear. They also have strong anti-fatigue properties. This helps to reduce worker strain during long operations.

As a professional supplier with years of experience, we can provide insulating mats that are tailored to your unique requirements. We can manufacture based on your size, thickness, color, and material specifications.

We support low minimum order quantities (MOQ), factory-direct pricing, and fast delivery for your bulk insulating mat orders. Request a quote today!

Electrical Mat Class Selection

Class 0
Class 0 Insulating Mat
Class 0
Class 2 Insulating Mat
Class 3
Class 3 Insulating Mat
Class 4
Class 4 Insulating Mat

Wide Range of Applications

Advantages of Our Electrical Insulating Mats

Non-Slip Properties
Non-Slip Properties

Our insulating mats are slip resistance to prevent falls and slips in your working environments.

Shock Protection
Shock Protection

With their non-conductive properties, these mats can provides worker with protection against electrical shocks.

Long Functional Life
Long Functional Life

These mats are made from elastomer and other rubber compounds that can withstand heavy use.

Resistance to Chemicals
Resistance to Chemicals

We designed these mats to resist chemicals such as acids and oils to ensure durability.

Easy to Clean
Easy to Clean

You can clean these mats easily using a mild soap and damp cloth.

Easy to Use
Easy to Use

Installing these mats are easy. You just lay them in front of electrical equipment and secure with adhesives.

Low Maintenance
Low Maintenance

Insulating mats are easy to maintain. This allows you to reduce maintenance and replacement cost.

Fully Certified
Fully Certified

We manufacture insulating mats according to international safety regulations and quality standards.

Enhanced Safety by Complying Safety Regulations

We manufacture insulating mats based on IEC61111:2009 and ASTM D178 standards with ribbed texture. Mats with dotted texture according to IS15652:2006 standards are also available. The corrugated surface and anti-skid feature of these mats improves ground traction. They help prevent slips and falls. Thus, reducing accidents and increase worker safety.

Insulating Mats
What Is an Insulating Mat?

HZ insulating mats are special rubber mats that protect people from electric shocks. When you stand on them near live electrical panels or equipment, the mat stops electricity from passing through your body. It keeps you safe and prevents serious accidents in workplaces or homes.

What Are The Safety Standards When Using Insulating Mats?
  • Check the mat if it has damage before using
  • The mat rating should match to your application voltage
  • Replace immediately if damaged or worn
  • Keep your mat clean
  • Make sure that the mat surface is dry before using
  • Stand on the mat when using
Why Do We Use Insulating Mats Around Electrical Panels?

These mats are placed in front of high-voltage panels, switchboards, or machines. They create a safety barrier between you and the ground, preventing electricity from reaching your body. Using them reduces the risk of accidents and ensures workers and electricians stay safe during maintenance or operation.

What Material Are HZ Insulating Mats Made Of?

Our mats are made from high-quality, electrically resistant rubber. This rubber is strong, flexible, and safe in different temperatures. It does not wear easily and provides long-lasting protection from electric shocks while remaining comfortable to stand on for workers or electricians.

Where Should You Place Insulating Mats for Safety?

Place the mat directly in front of electrical panels, switchgear, or equipment where people stand while working. Ensure the floor is flat, clean, and dry. Proper placement keeps workers isolated from the ground and helps prevent electricity from reaching their body during operation.

How Do You Care for or Clean an Insulating Mat?

Clean mats gently with mild soap and water if they get dirty. Do not use harsh chemicals, strong solvents, or expose them to high heat or direct sunlight for long periods. Dry them completely before use to maintain safety and long-lasting insulation properties.

How Long Can Insulating Mats Last?

With proper care, insulating mats last many years. Regularly inspect them for cracks, damage, or wear. Annual electrical testing is recommended, especially in high-voltage areas. Proper maintenance ensures the mat continues to provide full protection against electric shocks over time.

Is It Safe to Use Insulating Mats in Harsh Environments?

Of course! HZ mats resist oils, acids, and low temperatures, making them safe for industrial or electrical workplaces. They maintain strength and protection in tough conditions, ensuring workers stay safe even in challenging environments like factories, workshops, or outdoor electrical setups.

Can Insulating Mats Handle Outdoor Use?

Some mats are UV-resistant and weatherproof, suitable for indoor or outdoor use. Avoid long-term exposure to direct sunlight or extreme weather when possible. Proper storage and care help maintain their insulation quality and ensure safety for electricians and workers in outdoor environments.

Why Should Wholesalers Choose HZ’s Insulating Mats?

HZ mats meet top industrial safety standards, providing reliable protection against electric shocks. Wholesalers can offer long-lasting, high-quality mats for electricians, power plants, factories, and workshops. They are essential safety products that reduce accidents, improve workplace safety, and are valuable for every electrical work environment.

Rocket Your Business With HZ

Your Reliable Floor Mat Manufacturer In China

Scroll to Top